Watlow EZ-ZONE
®
PMI Controller 59 Chapter 4 Home Page
Changing the Set Point
You can change the set point by using the Up ¿ or Down ¯ keys when a prole is not run-
ning.
Starting a Profile from the Home Page
1. When at the Home Page, press the Advance Key to locate Prole Start and select the
le or step number to start. The upper display will show 1 and the lower display will show
p.st1.
2. Press the Up ¿ or Down ¯ key to choose the le or step number.
3. Press the Advance Key to select the Prole Action Request. The upper display will show
nonE and the lower display will show p.aC1.
4. Press the Up ¿ or Down ¯ keys to select the Prole Start. The upper display will show
prof and the lower display will show p.aC1.
5. Press the Innity ˆ Key to return Home. The Prole will Start
Ending a Profile from the Home Page
1. Press the Advance Key to select the Prole Action Request. The upper display will show
nonE and the lower display will show p.aC1.
2. Press the Up ¿ or Down ¯ keys to select the End. The upper display will show End and
the lower display will show p.aC1.
3. Press the Innity ˆ Key to return Home. The Prole will End.
Modifying the Home Page
1. Push and hold the Advance key and the Innity ˆ key for approximately six seconds.
Upon entering the Factory Page the rst menu will be the Custom Menu
CUst
.
2. Push the Advance key where the lower display will show CUst and the upper display
will show 1.
3. Push the Advance button where the prompt for the Process Value
aC.pu
will be dis-
played on top and Parameter par in the bottom. There are twenty positions available
that can be customized.
4. Pushing the Up ¿ or Down ¯ arrow keys will allow for a customized selection to be
made (see list of available parameters below).
Custom Menu Parameter Options
Description Prompt *
All Models
None Blank
Analog Input Value
ain1 ain2
Cal In Offset
i.Ca1 i.Ca2
Display Units
C_f1
Load Parameter Set
Usr.1 Usr.2
Alarm Low Set Point
a.Lo1 A.Lo2 a.Lo3 A.Lo4
Alarm High Set Point
a.hi1 a.hi2 a.hi3 a.hi4
Alarm Hysteresis
a.hy1 a.hy2 a.hy3 a.hy4

Table of Contents