PMI Controller • 89 • Chapter 5 Operations Page
Operations Page
Display
Parameter Name
Description
Range Default
Modbus
Relative Ad-
dress
CIP
Class
Instance
Attribute
hex (dec)
Pro-
fibus
Index
Pa-
ram-
eter
ID
Data
Type
and
Ac-
cess
**
P.sta
opEr
Profile Status Menu
* Available with PM8/9 only.
* Some parameters in the Profile Status Menu can be changed for the currently
running profile, but should only be changed by knowledgeable personnel and
with caution. Changing parameters via the Profile Status Menu will not change
the stored profile but will have an immediate impact on the profile that is
running. Changes made to profile parameters in the Profiling Pages will be
saved and will also have an immediate impact on the running profile.
p.str
P.Str
Profile Status
Profile Start
1 to 40 1 Instance 1
Map 1 Map 2
2520 4340
0x7A
(122)
1
1
204
22001 uint
W
p.ACr
PACr
Profile Status
Action Request
nonE None (61)
stEp Step (89)
End Terminate
(148)
rEsU Resume
(147)
paUs Pause (146)
prof Profile (77)
None Instance 1
Map 1 Map 2
2540 4360
0x7A
(122)
1
0xB (11)
205
22011 uint
W
stp
StP
Profile Status
Current Step
View the currently
running step.
1 to 40
0 (none)
- - - - Instance 1
Map 1 Map 2
2526 4346
0x7A
(122)
1
4
- - - -
22004 uint
R
s.typ
S.typ
Profile Status
Step Type
View the currently
running step type.
Ustp Unused Step
(50)
SoaH Soak (87)
ФІ.E Wait For Event
(144)
ФІ.pr Wait For
Process (209)
ФІ.bo Wait For
Process or Event
(210)
JL Jump (116)
End End (27)
CLoC Wait For
Time (1543)
ti Time (143)
ratE Ramp Rate
(81)
- - - - Instance 1
Map 1 Map 2
2544 4364
0x7A
(122)
1
0xD (13)
- - - -
22013 uint
R
t.sp1
t.SP1
Profile Status
*Target Set Point
Loop 1
View or change the
target set point of
the current step.
-1,999.000 to
9,999.000°F or units
-1,128.000 to
5,537.000°C
0.0°F
or units
-18.0°C
Instance 1
Map 1 Map 2
2542 4362
0x7A
(122)
1
0xC (12)
- - - -
22012 float
RW
** R: Read, W: Write, E: EEPROM, S: User Set