PM PID Controller • 66 • Chapter 7 Profiling Page
Profiling Page
Dis-
play
Parameter name
Description
Range Default Parameter
Appears in
Menu When
Modbus
Relative Ad-
dress
CIP
Class
Instance
Attribute
hex (dec)
Data
Type
&
Read/
Write
[~~JC]
[ JC]
Step Type Parameters
Jump Count
Set the number of jumps.
A value of 0 creates an
infinite loop. Loops can be
nested four deep.
0 to 9,999
0 Step Type is
set to Jump
Loop.
Instance 1
Map 1 Map 2
2594 4524
Offset to next
instance (Map
1 equals +50,
Map 2 equals
+100)
0x79 (121)
1 to 40
0xD (13)
uint
RWE
[~End]
[ End]
Step Type Parameters
End Type
Select what the controller will
do when this profile ends.
[`oFF] Control Mode set to
Off (62)
[Hold] Hold last closed-loop
set point in the profile (47)
[USEr] User, reverts to pre-
vious set point (100)
Off Step Type is
set to End.
Instance 1
Map 1 Map 2
2596 4526
Offset to next
instance (Map
1 equals +50,
Map 2 equals
+100)
0x79 (121)
1 to 40
0xE (14)
uint
RWE
Ent1]
[Ent1]
Step Type Parameters
Profile Event Output (A)
Select whether Event Out-
put 1 or 2 is on or off during
this step.
[`oFF] Off (62)
[``on] On (63)
Off Step Type is
set to Time,
Rate, Soak,
Wait Event,
Wait for Pro-
cess, Wait for
Both or Jump
Loop.
Instance 1
Map 1 Map 2
2582 4512
Offset to next
instance (Map
1 equals +50,
Map 2 equals
+100)
0x79 (121)
1 to 40
7
uint
RWE
[Ent2]
[Ent2]
Step Type Parameters
Profile Event Output (B)
Select whether Event Out-
put 1 or 2 is on or off during
this step.
[`oFF] Off (62)
[``on] On (63)
Off Step Type is
set to Time,
Rate, Soak,
Wait Event,
Wait for Pro-
cess, Wait for
Both or Jump
Loop.
Instance 1
Map 1 Map 2
2584 4514
Offset to next
instance (Map
1 equals +50,
Map 2 equals
+100)
0x79 (121)
1 to 40
8
uint
RWE
Note:
Some values will be rounded off to fit in the four-character display. Full values can be read with other interfaces.
R: Read
W: Write
E:
EEPROM
S:
User Set