EasyManua.ls Logo

Watts Tekmar Invita 564 - Heat Pump and Dual Fuel System Wiring; Heat Pump with Auxiliary Heat Wiring; Heat Pump with Dual Fuel Wiring

Watts Tekmar Invita 564
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2019 tekmar 564_Q - 10/19
7 of 16
Jumpers:
J1 = On
J2 = On
J3 = On
The thermostat operates high cost electric resistance heat when the heat pump is unable
to meet the building heating load.
Up to 2-Stage Heat Pump with Auxiliary Heat
HVAC Interface Module
564
Rh1
C
R
W1
Acc1
Acc1
Rh2
W2
Rc
Y1
G
Y2
To
T-Stat
AWAY
S1
S3
S2
Water
Detect
RH
3V3
SEN
COM
Acc2
O/B
Acc2
O/B
C
R
W1
Y1
G
Y2
O/B
70
Air
Handling
Unit
The thermostat operates the heat pump when the outdoor air temperature is above the
balance point setting and switches to the furnace when below.
Up to 2-Stage Heat Pump with 2-Stage Dual Fuel
HVAC Interface Module
564
Rh1
C
R
W1
Acc1
Acc1
Rh2
W2
Rc
Y1
G
Y2
To
T-Stat
AWAY
S1
S3
S2
Water
Detect
RH
3V3
SEN
COM
Acc2
O/B
Acc2
O/B
W1
C
W2
R
Y1
G
Y2
O/B
70
Air
Handling
Unit
Essential Settings:
Heating Type = Heat Pump
Equipment = 2 Heat Pump/1 Aux
Radiant Floor Heating = No
Essential Settings:
Heating Type = Heat Pump
Equipment = 2 Heat Pump/2 Aux
Radiant Floor Heating = No
Jumpers:
J1 = On
J2 = On
J3 = On

Related product manuals