Essential Settings:
Accessory Relay 1 or 2 = Dehumidifier
Dehumidifier Type = DX Coil
The thermostat operates the cooling system and runs the system fan at low speed to
dehumidify the air.
Dehumidification using a DX Coil
HVAC Interface Module
564
Rh1
C
R
W1
Acc1
Acc1
Rh2
W2
Rc
Y1
G
Y2
To
T-Stat
AWAY
S1
S3
S2
Water
Detect
RH
3V3
SEN
COM
Acc2
O/B
Acc2
O/B
C
R
W1
W2
Y2
Y1
G
Dehum
70
Air
Handling
Unit
HVAC Interface Module
564
Rh1
C
R
W1
Acc1
Acc1
Rh2
W2
Rc
Y1
G
Y2
To
T-Stat
AWAY
S1
S3
S2
Water
Detect
RH
3V3
SEN
COM
Acc2
O/B
Acc2
O/B
G
R
HRV / ERV
Ventilator
The Heat Recovery Ventilator (HRV) or Energy Recovery Ventilator (ERV)
operates to improve indoor air quality and recovers heat from exhaust air.
Essential Settings:
Accessory Relay 1 = Ventilation
HRV/ERV Ventilator
External Jumper Wires:
R to Acc1
R to O/B
HVAC Interface Module
564
Rh1
C
R
W1
Acc1
Acc1
Rh2
W2
Rc
Y1
G
Y2
HUM
HUM
To
T-Stat
AWAY
S1
S3
S2
Water
Detect
RH
3V3
SEN
COM
Acc2
O/B
Acc2
O/B
Humidifier
The thermostat operates a humidifier to increase relative humidity.
Humidifier
Essential Settings:
Accessory Relay 1 or 2 = Humidifier
Installing an outdoor sensor provides more accurate
outdoor temperature readings compared to using the
weather information from the internet.
Outdoor temperature is displayed on home screen.
Used to enable heat pump dual fuel switchover, warm
weather shut down, and cold weather shut down.
Outdoor Sensor
HVAC Interface Module
564
Rh1
C
R
W1
Acc1
Acc1
Rh2
W2
Rc
Y1
G
Y2
To
T-Stat
AWAY
S1
S3
S2
Water
Detect
RH
3V3
SEN
COM
Acc2
O/B
Acc2
O/B
tekmar Outdoor
Sensor 070