Do you have a question about the wattstopper LMCT-100 and is the answer not in the manual?
Category | Lighting Control |
---|---|
Input Voltage | 120-277 VAC |
Power Source | Line Voltage |
Enclosure Type | Plastic |
Weight | 0.5 lbs |
Control Type | On/Off |
Compatibility | Wattstopper |
Operating Temperature | -20°C to 50°C |
Dimensions | 2.5" |
Details accessing and viewing current sensor settings for parameter modification.
Explains how to modify and adjust various sensor parameters like Time Delay and Sensitivity.
Processes for sending, saving, and receiving sensor configurations.
Guides on entering, performing, and exiting sensor test mode for diagnostics.
Configuring loads using Push n' Learn (PnL) for selection, operation mode, and blink warning.
Processes for sending, binding, and navigating through load configurations.
Setup and operation for daylighting parameters based on sensor type and model.
Details for daylighting setup for LMLS-400, 500, and 600 models, including specific photosensor selection and search.
Configuring zones and operation modes (Switched, Bi-Level, Tri-Level, Dimmed) for LMLS-400/600.
Assigning loads for different operation modes and navigating through the process.
Specific assignment steps for Bi-Level and Tri-Level operation modes.
Configuring zones and operation modes for LMLS-500.
Assigning loads for different operation modes and navigating through the process.
Specific assignment steps for Bi-Level and Tri-Level operation modes.
Procedures for automatic and manual calibration of the LMLS-400 sensor.
Calibrating Switched, Bi-Level, Tri-Level, and Dimmed modes for daylighting control.
Adjusting and saving daylighting levels for day and night operations during calibration.
Establishing workplane illuminance and sensor light level relationship for LMLS-500.
Procedures for automatic and manual calibration of the LMLS-600 sensor.
Modifying daylighting setpoints, time delays, and ramp rates for LMLS-400.
Adjusting OFF Setpoint and Time Delays for zone settings.
Configuring Day/Night Setpoints, Ramp Up/Down, and Cut Off Delay for Dimmed mode.
Process for sending and saving configured zone settings.
Modifying daylighting setpoints, time delays, and ramp rates for LMLS-500.
Adjusting OFF Setpoint and Time Delays for zone settings.
Configuring Setpoint, Ramp Up/Down, and Cut Off Delay for Dimmed mode.
Modifying daylighting setpoints, time delays, and ramp rates for LMLS-600.
Adjusting OFF Setpoint and Time Delays for zone settings.
Configuring Setpoint, Ramp Up/Down, and Cut Off Delay for Dimmed mode.
Adjusting photocell light level, override mode, and time delays for LMLS-400/500.
Configuring Hold Off and Scenes Stop DL parameters for daylighting control.
Configuring Ignore After Hours and saving advanced settings.
Adjusting photocell light level, override mode, and time delays for LMLS-600.
Configuring Override Time and Hold Off parameters for daylighting control.
Configuring Scenes Stop DL and Ignore After Hours parameters.
Saving advanced settings and proceeding to recommissioning parameters.
Viewing Maximum Electric Light output and Daylight Ratio.
Configuring Force Open Loop and Recommissioning Threshold parameters.
Setting Recommissioning Delay and enabling Diagnostic Messages.
Selecting the control behavior of the photosensor (Normal, Test, Demo, Disable).
Configuring Scene, Load, and Rocker button types and their parameters.
Details on Scene button Type and Mode settings.
Setting Scene button Lock, Fade On, and Fade Off parameters.
Details on Load button Type and Mode settings.
Setting Load button Fade On, Fade Off, and Send/Next actions.
Parameters for Rocker buttons: Fade On, Fade Off, and Ramp Rate.
Setting the load type to Dimming or ON/OFF Switch.
Configuring Low Trim, High Trim, and Preset levels for dimming loads.
Setting Burn-in hours and saving dimming configuration.
Navigating to configure the next or prior dimming loads.
Adjusting the Trip Point parameter for switched loads.
Manually adjusting light levels of loads using the LMCT-100.
Viewing and changing network settings for communication modules.
Configuring LMSW buttons and DLM sensors for relay control.
Accessing device information and resetting Plug and Go states.
Setting the room mode to After Hours or Normal Hours for testing.
Troubleshooting display, response, and connectivity problems with the LMCT-100.
Troubleshooting lights not switching or dimming as desired under daylighting control.
Interpreting Red and Blue LED flashing patterns for sensor status and issues.