7
HT 2 Series Analog Hydraulic Tester
Tachometer
input
Pressure
gauge
Battery
voltage low
Battery
voltage ok
Display
(flow, temp, rpm)
Battery
cover
Selector
switch
Display - Large analog display. Automatically turns off if the unit is unused for more than
20 minutes.
Pressure gauge - Analog pressure gauge, filled with glycerine to ensure good dampening
when reading pulsating pressures.
Tachometer input - Connection socket for the optional infra-red phototachometer.
Selector switch - Turn the switch to select the required function.
OFF/RESET - Switches the tester off and resets the unit after automatic power shut off.
‘B’TEST - Checks the condition of the battery.
TEMP - Temperature is indicated on the display.
TACH - RPM is indicated on the display.
FLOW ‘HI’ - Flow is indicated on the ‘Hi’ scale of the display.
FLOW ‘LO’ - Flow is indicated on the ‘LO’ scale of the display.
Battery cover - Remove this to replace the battery.
Bi-Directional Loading Valve
The reverse flow valve gives positive shut-off and pressure control in both directions of flow.The
loading valve has two easily replaceable safety discs located in the valve assembly which
internally protect the tester and machine in both flow directions.