No� Fault Can be recognized by Possible cause Remedial measures
4
Front seal(s) / main seal(s)
are not spread sufficiently
Connector is seated too
loosely, it sits unsteadily
in the test piece
Wear
First check the test piece. If this is
defective, replace the test piece. If the
test piece is okay, replace the seals, see
Chapter 9. Inspection | Maintenance
Connector is not
correctly connected
Repeat the connecting procedure
The pilot pressure is not
sufficient
Increase pilot pressure
5
Connector wobbles despite
a correct connection to the
test piece
Incorrect connection
geometry at test piece
Wear on geometry of the
test piece’s connection
parts
Replace test piece
Wear on the connector’s
front seal(s) / main
seal(s)
Replace seals, see Chapter 9. Inspec-
tion | Maintenance
If you should encounter any other problems, please contact WEH or your responsible distributor.
MD-10187-L51-R1.3.0-03
Page 33
Operating instructions
AE