Instructions for Assembly
Item number 116519-0000 Subject to technical modifications
Version 4 23.04.2014 Page 36/47
Cassita II/Cassita II LED
7 Adjusting the arm position
The arm position needs to be adjusted if:
The drop profile needs to be set to a symmetrical position,
The arms come up to the housing differently.
1. Loosen the hexagonal socket head
screws (X) using an SW 4 Allen key.
2. Set the correct arm position.
3. Retighten the Allen screws.
7.1 Possible incorrect positions of the awning
1. Fabric / drop profile has moved
Remedy:
Slacken the fabric in the drop
profile
Slacken the drop profile support
bracket
Align the drop profile and the
folding arms and remount them
Refit the fabric in the drop profile
2. Folding arms are not symmetrical
Remedy:
Slacken the drop profile support
bracket
Slide the arms symmetrically
Refit the drop profile support
bracket