2. Operating instruction
Turn on the air switch on the switch box, the “Normal” indication lamp will light on and cooling fan rotates. Before
welding normally, set up parameters by adjusting knobs and switches on the front panel according to the selected mode.
Customer should refer to parameters defined in table 5 showing below:
Work piece thicknessmm
1
2
3
45
612
≥13
Electrode diametermm
1.5
2
3.2
3.24
45
56
Welding currentA
2040
4050
90110
90130
160250
250400