ICE MACHINE RUNS AND NO ICE IS PRODUCED
No water to ice machine
Correct water supply
Incorrect incoming water pressure
Water pressure must be 20-80 psi (1.4-5.5 bar)
Excessive mineral buildup
Clean and sanitize the ice machine
Ambient temperature is too high or low
Ambient temperature must be between 50°F and
110°F (10°C and 43°C)
Compressor relay inoperable
No voltage to coil or coil defective
Defective contacts
Compressor off on overload
Condenser fan motor defective
Incorrect flow to water cooled condenser
Ambient temperature too high
Condenser blocked
Faulty start components