INSTRUCTION MANUAL
WDT606 (Ultimate)
Thank you for purchasing this Welcare Digital Thermometer.
Please keep this instruction manual in a safe place where it is readily available.
Note: The illustrations in this manual may differ slightly from the product itself.
Read Instructions Carefully Before Use
Important Safety Information
Read this section thoroughly before using the product. Please ensure you observe the safety
instructions to avoid accidents, injury and damage.
Intended Purpose
This product is intended for the measurement of human body temperature only.
It is designed for private use.
The use of temperature readings for self-diagnosis is dangerous. Consult with a doctor
for the interpretation of results. Self-diagnosis may lead to the worsening of medical
conditions.
This product is not intended for use by persons (including children) with limited physical,
sensory or mental abilities or lacking experience and/or knowledge, unless they are
supervised by a person responsible for their safety or have received and understand the
instructions/ safety warnings for use of the product from this person in advance.
Safety Warnings
WARNING - KEEP BUTTON BATTERIES OUT OF REACH OF CHILDREN
Button batteries are hazardous (whether the battery is new or used).
Swallowing or insertion of a button battery into any part of the body can
cause severe or fatal injuries in 2 hours or less.
If you suspect your child/a person has swallowed or inserted a button
battery inside their body, medical attention should be sought immediately. You can also call
the Poisons Information Centre on 13 11 26 (Australia) or 0800 764 766 (New Zealand) for
24/7 fast, expert advice.
Dispose of products containing button batteries safely and according to current local regulations.
Tell others about the risk associated with button batteries and how to keep their children safe.
Keep the packaging, product and its components out of reach of children.
A high or prolonged fever requires medical attention, especially for young children.
Please contact a doctor.
This product is for oral, rectal or underarm use only. DO NOT attempt to take temperatures at
other sites, such as in the ear, as it may result in false readings and may lead to injury.
Oral use is only for ages 2+.
Avoid using the product during or within 30 minutes after strenuous exercise; a shower, bath or
sauna; using a cold compress; heavy alcohol consumption; smoking and food or drink intake.
DO NOT attempt measurements when the product is wet as inaccurate readings may result.
DO NOT bite on the product.
Avoid excessively bending the thermometric tip. DO NOT bend exi tip more than 45 degrees.
DO NOT force the product into the rectum. Stop insertion and abort the measurement when
pain is present.
DO NOT attempt rectal measurements on persons with rectal disorders.
DO NOT drop, step or place heavy objects on the product, as it is a precision instrument.
DO NOT store the product in the storage case when it is damp. Wipe it off with a clean
dry soft cloth rst.
DO NOT attempt to open or disassemble the product.
DO NOT place product near extreme heat as it may explode.
This product is equipped with a Lithium Manganese Button Battery. Failure to follow these
instructions could cause the battery to leak, become hot, explode or ignite and cause injury
and/or damage.
DO NOT expose to temperatures over 55 ˚C.
DO NOT use with other electrical or medical equipment simultaneously.
DO NOT use within 30cm of a mobile device or a device that emits electromagnetic elds
as this may cause interference with the functioning of the products.
DO NOT use or store the product in the following conditions:
Near sources of heat, in hot water, direct sunlight or high temperature
Moist or humid environments
Dusty locations
Near re, ammable gas, chemicals or oxygen rich environments
Locations easily subject to vibrations or shock or in a pressurized container
In high frequency or strong magnetic eld areas - e.g. surgical equipment,
MRI, CT, microwave oven
Package Contents
1 x Thermometer • 1 x Storage Case
1 x Battery (non-accessible) 1 x Instruction Manual & Warranty Information
Battery
When the low battery symbol is shown
on the bottom right of the screen the battery
life is depleted.
Dispose of as per instructions.
Non replaceable battery. Battery life is approximately 3 years.
Digital Thermometer Components
Before using the Digital Thermometer
Check the product is intact. DO NOT use if broken.
Read the instruction manual thoroughly before taking the measurement.
Allow product to rest for at least 30 minutes at room temperature (5˚C 32˚C).
The user must remain in a stable environment for at least 5 minutes prior to taking a reading.
Test the user’s temperature when they are well so there is a comparison when they are unwell.
Temperature readings are affected by many factors including physical exertion, the drinking
of hot or cold beverages before measurement, as well as measuring technique.
Avoid using the product during or within 30 minutes after exercise; a shower, bath or sauna;
using a cold compress; heavy alcohol consumption; smoking and food or drink intake.
Underarms must be clean and free of sweat, deodorant and scars, etc. for underarm use.
Always make sure the thermometric sensor is clean before each use.
When measuring the temperature of an infant, note that infant body temperature is generally
higher than adult body temperature and easily affected by external factors. For example, body
temperature tends to increase after nursing or crying. Therefore, it is recommended to take
measurements when the infant is calm.
Using the Digital Thermometer
The use of temperature readings for self-diagnosis is dangerous. Consult with a doctor for
the interpretation of results. Self-diagnosis may lead to the worsening of medical conditions.
Switching the measuring unit between °C and °F
While the product is Off, press and hold the On/Off button for 3 seconds to turn on. The
screen will show the last measured value. Press and hold the On/Off button until ºC or ºF
appears. Quickly press the On/Off button to alternate between ºC and ºF. The product will
automatically save your choice and run a self-check before going into measurement mode.
Selecting the Mode
While the product is Off, press and hold the On/Off button for 3 seconds. Press the button
again quickly to cycle through the four mode options (see below). When the desired mode
displays on screen, wait approx. 2 seconds for auto shut-off to select and save the mode.
Taking a Temperature Measurement
Note: The ambient temperature for use must be between 5-32°C. This product is a maximum
thermometer, i.e. the displayed temperature can increase slightly if measurement continues
after the beep. Holding the product too long may cause a higher ambient temperature reading
of the probe. This could make the body temperature measurement lower than usual.
Before using, please disinfect the thermometric tip (refer to Cleaning section).
1. While the thermometer is off, press
and hold the On/Off button for
3 seconds.
7. The three dashes (---) will ash sequentially throughout the testing process. As soon as the
temperature value is reached (approx. 5 seconds) ashing stops and an alarm will beep for
approximately 10 seconds. The measured reading will appear on the LCD simultaneously.
8. Once the beeping has stopped the measurement is completed. Remove the product
from the measurement site.
9. The highest temperature measured appears on the screen.
10. Turn the product off by pressing the ON/OFF button.
11. Although the product will turn off automatically after 10 minutes, to conserve power it
is recommended to turn the product off manually after each reading.
12. The reading will automatically be stored in the memory.
13. The measurement continues even after the beeping has stopped. In order to achieve better
body temperature measurement results, it is recommend to keep the probe in mouth and
rectum for an additional 2 minutes, or in armpit about for an additional 5 minutes after the
beeping sound.
Note: Result times may vary due to the individual and method used.
Memory Function
The last measured temperature will display on the screen for approximately 2 seconds after
the self-check when the product is turned on.
Methods of Measuring Temperature
Note: Measurement accuracy cannot be assured when the method used to measure the
temperature is incorrect. If multiple measurements are taken over a period of time, it is
important to use the same method of measurement each time so the results are comparable,
i.e. do not interchange between oral, rectal or underarm measurements. If taking multiple
measurements within a short period of time, allow the thermometer to return to room
temperature prior to taking each measurement.
˚F to ˚C ˚C to ˚F
Oral
mode
Underarm
mode
Rectal
mode
Bath
mode
ON/OFF button
LCD screen
Thermometric tip
Thermometric sensor
BEEP
Storage Case
2.
Press the On/Off button.
The product will run a
self-check test, during
which all the digital
segments appear on the screen.
3. The memory will show
the last reading on the
screen for 2 seconds.
4. After showing the mode
of measurement, the
thermometer will enter
the testing mode.
5. Refer to Methods of measuring
temperature section for placement
instructions.
6. Keep the user still during the
measurement.
MEMORY
(last reading)
Welcare_DigitalTherm_WDT606-Manual-Working.indd 1Welcare_DigitalTherm_WDT606-Manual-Working.indd 1 29/7/21 4:18 pm29/7/21 4:18 pm
Question and Answer IconNeed help?

Do you have a question about the Welcare WDT606 (Ultimate) and is the answer not in the manual?

Overview

The Welcare WDT606 (Ultimate) is a digital thermometer designed for measuring human body temperature. It is intended for private use and provides predictive temperature readings.

Function Description:

The thermometer is used to measure body temperature orally, rectally, or under the arm. It features a thermometric tip and sensor to detect temperature. The device displays the temperature reading on an LCD screen and includes an ON/OFF button for operation. It can switch between Celsius (°C) and Fahrenheit (°F) units and offers four measurement modes: Oral, Underarm, Rectal, and Bath. The device stores the last measured temperature in its memory. A beep sound indicates when a measurement is complete, and the highest temperature measured appears on the screen. For infants, it is recommended to take measurements when the infant is calm, as their body temperature can be easily affected by external factors.

Important Technical Specifications:

  • Model No.: WDT606 (Ultimate)
  • Power Type/Rating: Lithium Manganese Button Battery (CR2032 3V DC)
  • Battery Life: Approximately 200 hours of continuous operation or 3 years with 1 measurement per day. The battery is non-accessible and non-replaceable, with an approximate life of 3 years. A low battery symbol appears on the screen when the battery life is depleted.
  • Thermometer Type: Digital Thermometer (Predictive)
  • Measurement Range: 32.0 - 42.9°C / 89.6 - 109.2°F
  • Measurement Scale Increments: 0.1°C / 0.1°F
  • Measurement Accuracy:
    • ±0.1°C (±0.2°F) during 35.5°C~42.0°C (95.9°F~107.6°F) at 18°C~28°C (64.4°F~82.4°F) ambient operating range.
    • ±0.2°C (±0.4°F) for other measuring and ambient operating range.
  • Operating Conditions:
    • Temperature: 5 - 40°C
    • Humidity: 15% - 95% RH (non-condensing)
    • Atmospheric pressure: 700hPa to 1060hPa
  • Storage/Transport Conditions:
    • Temperature: -20 - 55°C
    • Humidity: 15% - 95% RH (non-condensing)
    • Atmospheric pressure: 700hPa to 1060hPa
  • Dimensions: 13.4cm × 3.1cm × 1.6cm (L×W×H) (out of packaging)
  • Weight: Approximately 23g including battery
  • IP Rating: IP27 (Protection against particles >12.5mm and protected from immersion between 15 cm and 1 m in depth).
  • Materials: ABS + TPE plastic, Stainless Steel, Silica Gel, LCD Screen, Nickel Plated Iron Safety Screw.
  • Applied Part: Type BF Equipment (Degree of protection against electric shock).
  • Compliance: EC directive 93/42/EEC (Medical Device Directive) and European Standard EN124703:2000+A1:2009. Conforms to EN60601-1-2:2015 Electro Magnetic Compatibility (EMC) standard.

Usage Features:

  • Before Use: Check the product for damage, read the manual, allow it to rest at room temperature (5°C – 32°C) for at least 30 minutes, and ensure the user remains in a stable environment for 5 minutes prior to reading. Disinfect the thermometric tip before each use.
  • Turning On/Off: Press and hold the ON/OFF button for 3 seconds to turn on. The device performs a self-check and displays the last measured value. Press the ON/OFF button to turn it off manually, though it will auto-shut off after 10 minutes.
  • Unit Switching (°C/°F): While off, press and hold the ON/OFF button for 3 seconds. Once the last measured value appears, continue holding until °C or °F appears, then quickly press the ON/OFF button to toggle. The selection is automatically saved.
  • Mode Selection: While off, press and hold the ON/OFF button for 3 seconds. Then, quickly press the button again to cycle through Oral, Underarm, Rectal, and Bath modes. The desired mode is selected by waiting approximately 2 seconds for auto shut-off.
  • Oral Mode (Ages 2+ only): Place the thermometric sensor under the tongue in one of the two heat pockets at the back, ensuring constant contact with tissue and the screen facing upwards. Keep the mouth closed and breathe through the nose. Do not eat or drink before measurement.
  • Underarm Mode (Axillary): Wipe off perspiration and deodorant. Place the sensor in the center of the armpit, touching the skin, with the screen facing inwards. Hold the product in place by applying slight pressure, positioning it at a 35-45 degree angle.
  • Rectal Mode: Lubricate with a water-soluble gel (do not use petroleum jelly). Gently insert the sensor no more than 2cm into the rectum. Stop if pain occurs. This is considered the most accurate method for core body temperature, especially for young children.
  • Bath Mode: Place the thermometric sensor into the bath water. The display will show "Lo" and °F or °C will flash.
  • Measurement Process: After entering testing mode, three dashes will flash sequentially. Once the temperature value is reached (approx. 5 seconds), flashing stops, an alarm beeps for 10 seconds, and the reading appears on the LCD. The measurement continues even after the beep; for better results, keep the probe in the mouth/rectum for an additional 2 minutes, or in the armpit for an additional 5 minutes.
  • Memory Function: The last measured temperature is automatically stored and displayed for 2 seconds upon turning on the device.
  • Safety Warnings: Keep button batteries out of reach of children. Seek immediate medical attention if a battery is swallowed or inserted. Dispose of batteries and products safely. Do not bend the flexi tip more than 45 degrees, force the product into the rectum, drop it, store it damp, open or disassemble it, or place it near extreme heat. Avoid exposure to temperatures over 55°C. Do not use with other electrical/medical equipment simultaneously or within 30cm of mobile devices. Avoid using in extreme environments (heat, humidity, dust, flammable gas, high frequency/magnetic fields).

Maintenance Features:

  • Cleaning: Always clean/disinfect before and after use. Use a damp cloth with 70% medical alcohol. Rinse only the thermometric tip under slow running cold water and dry with a soft cloth. Do not use harsh chemical cleaning agents, immerse the product in water, rinse with hot water over 50°C, soak in alcohol for long periods, or use ultrasonic washing.
  • Storage: Wipe away dirt and dust. Store in its protective cover when not in use. Do not store damp. Keep in a safe, cool, dry place, away from children. Do not place heavy objects on it.
  • Troubleshooting: The manual provides solutions for error codes such as "Lo" (temperature lower than 32.0°C), "Hi" (temperature higher than 42.9°C), "Er1" (thermometer moved during measurement), and "Er2" (measurement time exceeds 15 seconds or ambient temperature too low). A flashing battery icon indicates a dead battery, requiring disposal of the unit.
  • Calibration: The product is initially calibrated at manufacture. Re-calibration is generally not required if used according to instructions. Contact service if out of specification.
  • Disposal: Treat as electronic waste and dispose of responsibly according to local regulations at the end of its life.

Welcare WDT606 (Ultimate) Specifications

General IconGeneral
BrandWelcare
ModelWDT606 (Ultimate)
CategoryThermometer
LanguageEnglish