AIR CONDITIONER
Duct type
REFRIGERANT R410A
INVERTER
SERVICE MANUAL
INDOOR
WHM24DMA21S
WHM36DMA21S
WHM48DMA21S
WHM60DMA21S
OUTDOOR
WHM24SZA21S WHM36SZA21S WHM48SZA21S
WHM60SZA21S
, WESTINGHOUSE, and INNOVATION YOU CAN BE SURE OF are trademarks of Westing house
Electric Corporation. Used under license by FUJITSU GENERAL AMERICA, INC. All Rights Reserved.
2021.12.14

Other manuals for Westinghouse WHM36DMA21S

Questions and Answers

  • R
    Richard FrankAug 9, 2025
    What to do if my Westinghouse Air Conditioner can not start up?
    • F
      fballAug 9, 2025
      If your Westinghouse Air Conditioner won't start, begin by checking the power supply circuit. Look for any tripped breakers or blown fuses. Measure the insulation resistance to ground to check for leakage. Inspect the power supply circuit for defective contacts or leak current. Ensure the remote controller is properly set and, if needed, change the batteries.
  • F
    floresjaredAug 15, 2025
    Why is my Westinghouse WHM36DMA21S Air Conditioner not cooling/heating well?
    • C
      Christopher RossAug 16, 2025
      If your Westinghouse Air Conditioner isn't cooling or heating properly, several factors could be responsible. First, try cleaning the heat exchanger of the outdoor unit, such as the condenser. Also, ensure there are no heating devices operating indoors. Maintaining good air tightness indoors can help, so limit frequent opening and closing of doors and windows. Check for any obstructions blocking the outdoor heat exchanger, and remove them. Finally, double-check the temperature settings to ensure they are correctly configured.
  • D
    Dominique SanchezAug 21, 2025
    How to fix water leakage from my Westinghouse Air Conditioner?
    • S
      Sarah WiseAug 21, 2025
      If your Westinghouse Air Conditioner is leaking water, it could be due to a blocked or broken drainage pipe. In this case, change the drainage pipe. Another potential cause is that the wrap of the refrigerant pipe joint is not completely closed. To fix this, re-wrap the joint tightly.
  • K
    Kayla AndersonAug 28, 2025
    Why does the compressor in my Westinghouse WHM36DMA21S Air Conditioner start and stop frequently?
    • M
      Melissa FigueroaAug 28, 2025
      If the compressor in your Westinghouse Air Conditioner starts and stops frequently, the air inlet and outlet might be blocked. Remove any obstacles to resolve this issue.
  • B
    Brittney ButlerSep 2, 2025
    What to do if my Westinghouse WHM36DMA21S makes sounds from deforming parts?
    • L
      Lisa WilliamsonSep 2, 2025
      The sound from deforming parts in your Westinghouse Air Conditioner is not abnormal, and the sound will disappear soon.

Summary

Safety Summary

Important Notice

Key safety warnings and product usage guidelines for hazard prevention.

Specifications

Dimensions

Installation Space Requirements

Refrigerant Circuit Diagrams

Piping and Refrigerant Charge

Component Checks

Parts Inspection

Outdoor Unit DIP Switch Settings

Wiring Diagrams

Troubleshooting and Fault Codes

General Malfunctions Guide

Common issues, their causes, and solutions for air conditioner malfunctions.

Outdoor Unit Fault Code Table

Comprehensive table detailing outdoor unit fault codes, descriptions, causes, and solutions.

Drive Fault Codes (24 K;36 K Models)

Specific fault codes and troubleshooting steps for 24K/36K drive systems.

Drive Fault Codes (48 K;60 K Models)

Specific fault codes and troubleshooting steps for 48K/60K drive systems.

Westinghouse WHM36DMA21S Specifications

General IconGeneral
RefrigerantR410A
Weight (Outdoor Unit)121.3 lbs
Cooling Capacity36, 000 BTU/h
TypeDuctless Mini Split
Heating Capacity36, 000 BTU/h
Power Supply208-230V, 60Hz, 1 Phase
Outdoor Unit Noise Level56 dB