EasyManua.ls Logo

Westward 22XP38 - Working Area and Safety; Working Area Safety Precautions; Electric Safety; GFCI Testing and Extension Cord Use

Westward 22XP38
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Westward Operating Instructions and Parts Manual
22XP38, 22XP39
Drain Cleaning Machine
permanentgroundsuchasaproperlygroundedoutletboxcover.Whenevertheadaptorisused,
itmustbeheldinplacebythemetalscrew.
WorkingAreaandSafety
1. Donotletwatergetintothepowertools.Ifthemachineiswet,donotoperateituntilitis
dry.Donotoperatemachinewhenitisstandinginwater.Thiswillincreaseriskofelectrical
shock.
2. Wearsafetyequipment(glovesandrubber
soled,nonslipshoes)andapplysafety
procedureswhenworkingareaiswet.Placethemachineonadrysurface.
3. Neveroperatemachinesinexplosiveenvironments,includingareaswithflammableliquids,
gasesordust.Powertoolscreatesparkswhichmayignitethedustorfumes.
4. Becautiouswhen
cleaningdrainswithcleaningchemicalsbeingapplied.Donotletthe
chemicalsdirectlycontactskin,eyesand/orthecable.Thesechemi calscancauseserious
burnstotheskinandeyesaswellasdamagingthecable.
5. Haveasecondpersonsupervisewhenworkinginanarrowspaceorspecialenvironment,
suchasinaboilerroom,insideapipeoronawetsurface.Failuretodosomaycause
seriousinjuryordeath.
6. Keepbystanders,children,andvisitorsawaywhileoperatingthepowermachine.
Distractionsbyothersmayleadtolosingcontrol.
7. Keepworkingareawelllit,
neatandclean.Darkzonesandclutteredmessescause
unpredictableaccidents.
ElectricSafety
1. ThemachineisequippedwithaGroundFaultCircuit
Interrupter(GFCI),whichprotectsyouagainstshockifshort
circuitshouldoccur.Checkthatthereceptacleisproperly
grounded.TesttheGFCIbeforeeachuse.Thetestingprocedure
isgivenbelow:
a) Plugmachineintoareceptaclewiththemachinespecified
voltage.
b) Pushthetestbutton.Indicatorlightwillgooutandpower
tomachinewillcutoff.
Iflightdoesnotgooutwhenthetest
buttonispushed,equipmentshouldnotbeuseduntil
properrepairsorreplacementtotheGFCIaremade.
c) Torestorepoweraftertest,pushresetbutton.
Withtheresetbuttonuntouched,ifthemachinedoesnotstart,or
stopswhilerunning,orifyouexperienceamildshock,donotusethemachine!Have
itrepairedorreplacedbyalicensedtechnician.
Whenusinganextensioncord,theGFCIonthedraincleanerdoesnot
protecttheextensioncord.IftheoutletisnotGFCIprotected,itisadvisabletousea
plugintypeGFCIbetweentheoutletandtheextensioncordtoreducetheriskof
shockifthereis
afaultintheextensioncord.
2. Whenworkingwiththemachineoutside,useaspeciallydesignedoutdoorextensioncord.
Thiskindofcordreducestheriskofelectricshock.Useonlythreewireextensioncords
whichhavethreeprongedgroundingplugsandthreepolereceptacleswhichacceptthe
tool’s
plug.Useofotherextensioncordswillnotgroundthetoolandincreasetheriskof
electricshock.Insufficientconductorsizewillcauseexcessivevoltagedropandlossof
power.Whenusingextensioncords,aGFCImustbeusedincircuitboxesoroutlet
receptacles.ExtensioncordswithoutaGFCIcan
alsocauseelectricshock.

Related product manuals