Display Defect Description Solutions
H1 Motor high
temperature
1. Stop riding or ride scooter at low speed,
avoid climbing.
2. Check whether the motor wire is
damaged, and whether the temperature
signal wire of the motor wire is short-
circuited to the ground.
3. Replace the motor.
H2 Control board high
temperature
1. Stop riding or ride scooter at low speed,
avoid climbing.
2. Check the installation of control board
radiator.
3. Replace the control board.
H3 Control board
super high
temperature
1. Stop riding or ride scooter at low speed,
avoid climbing.
2. Check the installation of control board
radiator.
3. Replace the control board.
LR Over current 1. Release the accelerator.
2. Restart.
3. Replace the control board.
S1 Short circuit
1. Get the motor disconnected and restart
scooter. If this alarm has not been
cleared, get control board replaced;
otherwise, all-clear, replace the motor.