22
EN
INSTRUCTION MANUAL · AIR CONDITIONER
u QUIET button
Press this button, the Quiet status is under the Auto Quiet mode (display “
and “Auto” signal) and Quiet mode (display “ “ singal) and Quiet OFF (there
is no signal of “ “ displayed), after powered on, the Quiet OFF is defaulted.
Under the Quiet mode (Display “ “ signal). The Quiet function is only available
for some models.
i SLEEP button
Press this button, can select Sleep 1 ( ), Sleep 2 ( ), Sleep 3 ( ) and cancel
the Sleep, circulate between these, after electried, Sleep Cancel is defaulted.
Sleep 1 is Sleep mode 1, in Cool, Dehumidify modes: sleep status after run for
one hour, the main unit setting temperature will increase 1°C, 2 hours, setting
temperature increased 2°C, the unit will run at this setting temperature; In Heat
mode: sleep status after run for one hour, the setting temperature will decrease
1°C, 2 hours, setting temperature will decrease 2°C, then the unit will run at this
setting temperature.
Sleep 2 is sleep mode 2, that is air conditioner will run according to the
presetting a group of sleep temperature curve. In Cool mode:
1. When setting the initial temperature 16°C-23°C, after turned on Sleep
function, the temperature will be increased 1°C in every hour, after 3°C
the temperature will be maintained, after 7hours, the temperature will be
decreased 1°C, after that the unit will keep on running under this temperature;
2. When setting the initial temperature 24°C-27°C, after turned on Sleep
function, the temperature will be increased 1°C in every hour, after 2°C
the temperature will be maintained, after 7hours, the temperature will be
decreased 1°C, after that the unit will keep on running under this temperature;
3. When setting the initial temperature 28°C-29°C, after turned on Sleep
function, the temperature will be increased 1°C in every hour, after 1°C
the temperature will be maintained, after 7hours, the temperature will be
decreased 1°C, after that the unit will keep on running under this temperature;
4. When setting the initial temperature 30°C, under this temperature setting,
after 7hours, the temperature will be decreased 1°C, after that the unit will
keep on running under this temperature;
In Heat mode:
1. Under the initial presetting temperature 16°C, it will run under this setting
temperature all along.
2. Under the initial presetting temperature17°C-20°C, after Sleep function
started up, the temperature will decrease 1°C in every hour, after 1°C
decreased, this temperature will be maintained.
3. Under the initial presetting temperature 21°C-27°C, after Sleep function
started up, the temperature will decrease 1°C in every hour, after 2°C
decreased, this temperature will be maintained.