30
EN
INSTRUCTION MANUAL · AIR CONDITIONER
ERROR CODE
When air conditioner status is abnormal, temperature indicator on indoor unit
will blink to dispaly corresponding error code. Please refer to below list for
identication of error code.
Error code Troubleshooting
E5 Over current protection: Unstable supply voltage,the heat
exchangers are too dirty,fan speed is not normal, compresor
failure, oil or gas leak.
E8 High temperature resistant protection: Refrigerant leak, fan
motor failure, too dirty dust lters or heat exchangers.
U8 Indoor fan motor malfunction: Fan motor failure, Indoor PCB
failure.
H6 Lock of indoor fan motor: Fan motor is broken,fan motor is
blocked.
E6 Communication malfunction: Wrong wiring between indoor and
outdoor unit,PCB indoor/outdoor malfunction.
C5 Malfunction of jumper cap: Missing jumper cap on PCB indoor,
PCB is broken.
F0 Refrigerant recovery mode: Leakage of refrigerant, refrigerant
catering
F1 Indoor ambient sensor is broken.
F2 Indoor evaporator sensor is broken.
Note: If there’re other error codes, please contact qualied professionals for
service.