5.2 Technical data
5.3 Included in delivery
• Lifting system
• Operating manual
For HiSewlift 3-15: outlet elbow (x1), 3-outlet bushing (x1), clamp 32x55 (x4),
clamp 25x40 (x1), clamp 20x32 (x1), hose (x1), Ty Wrap (x1), clamp 90x110 (x1),
inlet elbow (x1), screw (x2), fixation strip (x2).
For HiSewlift 3-35: outlet elbow (x1), 3-outlet busching (x1), clamp 32x55 (x8),
clamp 25x40 (x1), clamp 20x32 (x1), hose (x1), Ty Wrap (x1), clamp 90x110 (x1),
inlet bushing (x3), lateral inlet bushing (x1), vis(x2), fixation strip(x2).
For HiSewlift 3-I35: outlet elbow (x1), 3 outlet bushing(x1), clamp 32x55 (x4),
clamp 25x40 (x1), clamp 20x32 (x1), inlet bush (x1), lateral inlet plug (x2), screw
(x2), fixation strip(x2).
5.4 Description
HiSewlift 3-15 and HiSewlift 3-35 (Fig. 2)
1 - Bushing
2 - Elbow
3 - 3-outlet bushing
4 - Plug
5 - Fixation strip (x2)
6 - Screw (x2)
7 - Screw clamp (x2 for each part number)
8 - Hose
9 - Ty-Wrap
Hydraulic data HiSewlift 3-15 HiSewlift 3-35 HiSewlift 3-I35
Maximum vertical delivery 5 m 5 m 5 m
Maximum Horizontal delivery 90 m 90 m 90 m
Maximum altitude 1000 m 1000 m 1000 m
DN of suction connection DN40 DN40 DN40
DN of pressure connection DN32-28-22 DN32-28-22 DN32-28-22
Number of connections
1 for toilet + 1 1 for toilet + 3 1 for toilet + 3
Temperature range
Fluid temperature range +5°C to +35°C +5°C to +35°C +5°C to +35°C
Ambient temperature Max. +40°C Max. +40°C Max. +40°C
Electrical data
Motor protection rating IP 44 IP 44 IP 44
Insulation class Class I Class I Class I
Frequency 50 Hz 50 Hz 50 Hz
Voltage 220/240 V 220/240 V 220/240 V
Rated current 1.9 A 1.9 A 1.9 A
26
English
09/2014