EasyManua.ls Logo

Wilo Medana CH1-LC - Data table

Wilo Medana CH1-LC
132 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
en Product information
22 WILO SE 02/2021
Example: Medana CH1-LC.404-5/E/A/10T
1
Series level (1 = entry level, 3 = standard level, 5 = premium level)
LC
L = Long shaft
C = Pump housing in cast iron
4
Delivery rate in m
3
/h
04
Number of impellers
5
Pump housing in cast iron + hydraulics in 1.4307 stainless steel
E
EPDM seal
A
A = Frequency 50Hz/ single-phase/ 230V
B = Frequency 60Hz/ single-phase/ 220V
C = Frequency 60Hz/ single-phase/ 230V
D = Frequency 50Hz/ three-phase/ 400V
E = Frequency 50Hz/ three-phase/ 230–400V
F = Frequency 60Hz/ three-phase/ 220–380V
G = Frequency 60Hz/ three-phase/ 265–460V
I = Frequency 60Hz/ three-phase/ 460V
10
Maximum pressure of the pump in bar
T
Screwed connections
3.2 Data table
Maximum utilisation pressure
Maximum operating pressure
See pump type key on rating plate and paragraph 3.1
Maximum suction pressure
6bar
Notice: the suction pressure (Pinput) + the pressure at
zero delivery rate (Pzero delivery rate) must always be
lower than the maximum authorised operating pressure
(Pmax). Pinput +Pzero delivery rate≤ Pmax. Refer to
the pump rating plate for the maximum operating pres-
sure: Pmax.
Temperature range
Fluid temperature
-20°C to +120°C with EPDM seals
-20°C to +90°C with VITON seals
(only on version L)
Ambient temperature
-15°C to +50°C
Electrical data
Motor protection rating
See plate
Insulation class
See plate
Frequency
See plate
Voltage
See plate
Motor efficiency
See plate
Other characteristics
Humidity
<90% without condensation
Altitude
≤1000m (>1000m on request)
Noise level
Motor power (kW)
Frequency (Hz) Phase dB(A) at 1m, BEP tolerance
0–3dB(A)
0.37
50 3 54
0.55
50 3 54
0.75
50 3 55

Table of Contents