en Product information
22 WILO SE 02/2021
Example: Medana CH1-LC.404-5/E/A/10T
1
Series level (1 = entry level, 3 = standard level, 5 = premium level)
LC
L = Long shaft
C = Pump housing in cast iron
4
Delivery rate in m
3
/h
04
Number of impellers
5
Pump housing in cast iron + hydraulics in 1.4307 stainless steel
E
EPDM seal
A
A = Frequency 50Hz/ single-phase/ 230V
B = Frequency 60Hz/ single-phase/ 220V
C = Frequency 60Hz/ single-phase/ 230V
D = Frequency 50Hz/ three-phase/ 400V
E = Frequency 50Hz/ three-phase/ 230–400V
F = Frequency 60Hz/ three-phase/ 220–380V
G = Frequency 60Hz/ three-phase/ 265–460V
I = Frequency 60Hz/ three-phase/ 460V
10
Maximum pressure of the pump in bar
T
Screwed connections
3.2 Data table
Maximum utilisation pressure
Maximum operating pressure
See pump type key on rating plate and paragraph 3.1
Maximum suction pressure
6bar
Notice: the suction pressure (Pinput) + the pressure at
zero delivery rate (Pzero delivery rate) must always be
lower than the maximum authorised operating pressure
(Pmax). Pinput +Pzero delivery rate≤ Pmax. Refer to
the pump rating plate for the maximum operating pres-
sure: Pmax.
Temperature range
Fluid temperature
-20°C to +120°C with EPDM seals
-20°C to +90°C with VITON seals
(only on version L)
Ambient temperature
-15°C to +50°C
Electrical data
Motor protection rating
See plate
Insulation class
See plate
Frequency
See plate
Voltage
See plate
Motor efficiency
See plate
Other characteristics
Humidity
<90% without condensation
Altitude
≤1000m (>1000m on request)
Noise level
Motor power (kW)
Frequency (Hz) Phase dB(A) at 1m, BEP tolerance
0–3dB(A)
0.37
50 3 54
0.55
50 3 54
0.75
50 3 55