Maintenance55524/A1
RT-flex58T-D
Winterthur Gas & Diesel Ltd.
2/ 3
Screw two RUD-eye bolts 94040M16 into housing of supply unit 1 as shown
in Fig. ’D’.
Suspend lifting tool 94557 on manual ratchets ’MR’ (WLL 2000 kg each) and
connect these with RUD-eye bolts.
Tauten manual ratchets ’MR’.
Loosen screws 11 and remove them together with the distance sleeves.
Loosen screws 5, 6, 7 and cap screws 8.
Bring the supply unit in horizontal position with manual ratchets ’MR’.
Carefully move supply unit away.