Mount pin 94665 and roller 94665A on the corresponding support as shown in
Fig. ’C’. Lock pin with its double spring clip 15.
Fasten manual ratchet ’H1’ to the upper support 16 and connect it to cover 1
via roller 94665A.
Loosen screws to cover 1, lower it to bottom plate and and push it to the side.
Remove vent pipe 6 and drain pipe 7.
Remove cooling water inlet pipe 8 and cooling water outlet pipe 9 between
connection chamber 3 and butterfly valve 10.
Loosen screws 5 of the screw connection to tube stack 12 for scavenge air
receiver 4 (Fig. ’A’).
Fix roller plate 94662(A) at connection chamber 3. Press the rollers a little
against rails 11 by means of setscrews ’ST’ (Fig. ’C’).
Loosen the tube stack from the scavenge air receiver with the aid of jack
screws. As soon as the tube stack is free, lift it a little by tightening setscrews
’ST’.
C
AH
a, b
010.571/02
ba11
FIXED SIDE
ZS
I
II
94662(A)
3
I
94665 94665A15
16
II
III
III
010.570/02
3TR 12
1
II
ST
2013
Scavenge Air Cooler: Removal and Fitting of Tube Stack