Maintenance66062/A1
RT-flex58T-D
Winterthur Gas & Diesel Ltd.
6/ 6
F
ZS
3
TR12
b a94662(A) 11 94663A(B)
010.576/02
EXPANSION
SIDE
3.1 Final assembly
Screw in as much as possible of screws 5.
Push / pull tube stack 12 towards the air side by means of screws 13, 13a.
Remove pulley plate 94662(A).
Screw in remaining screws 5. Subsequently tighten all screws.
Remove assembling device & pulley support.
Connect piping, close drains 7, open vents 6
and butterfly valves 10.
Start cooling water pump and check tube
stack for possible leaks.
Fit cover 1 and seal it with non-hardening
sealing compound.
Remark: The connection of cooling water outlet 9
is arranged in such a way that it is always near to
the scavenge air inlet into the receiver.
12
I
010.847/03
14
G
94662(A)
5
018.985/09
I
2013
Scavenge Air Cooler: Removal and Fitting of Tube Stack