Maintenance
6708−1/A1
RT-flex58T-D
Winterthur Gas & Diesel Ltd.
1/ 3
Tools: Key to Illustrations:
2 Manual ratchets (WLL 800 kg) 94016 (H1) 1 Receiver 10 Tension washer
2 Air flaps 11 Door
3 Water separator 12 Coupling
4 Cover on WS 13 Water drain
5 Seal 14 Cover
6 Screw 15 Screw
7 Plate
8 Screw
9 Spring pack AF Seating face
1. General
The water separator should be inspected after completing the first operating year.
The cleaning interval for future servicing should be established on the basis of the
degree of contamination found. If the air suction filter of the exhaust gas turbochar-
ger is well maintained, the degree of contamination of the water separators should
not be considerable.
2. Inspection
⇒ Open door 11 on one side of the scavenge air receiver.
⇒ Enter the scavenge air receiver, tilting up air flaps 2, and check water separa-
tor 3 for damage and fouling.
⇒ Separate couplings 12 from water drains 13.
Check the water drains for free passage.
A
4
018.958/09
2
11
12
3
13
2013
Water Separator
Maintenance of Water Separator 1-part Water Separator
CHECK