Maintenance
67081/A2
RT-flex58T-D
Winterthur Gas & Diesel Ltd.
3/ 3
4. Cleaning
The water separator should be cleaned with the same media as used for cleaning
the scavenge air cooler in operation.
D Do not use any sharp tools for cleaning.
5. Fitting
D Before fitting the water separator, its location in the scavenge air receiver
must be thoroughly cleaned and the water drains checked for free flow.
Apply a high-temperature (approx. 300 _C) silicone jointing compound e.g.
COLTOGUN to all seating faces ’AF’, thus avoiding an air bypass between
frame and wall.
Lift water separator 3 by means of manual ratchets ’H1’ and fit (loose) screws
12 together with sleeves 13, pressure springs 14 and discs 15.
Pull water separator up until it rests on sleeves 13 (paying attention to clear-
ance ’x
1
’ on bottom side), i.e. that it not protrudes anymore (distance ’x’)
compared with receiver 1.
Fasten intermediate flange 6 with screws 5 and carefully lower water separa-
tor onto the intermediate flange.
Tighten screws 12.
Fit and tighten screws 7 together with spring washer 8 and tension sleeves 9.
Remove manual ratchets ’H1’.
Fit cover 11. Close door 16 and hinged cover 4, and reconnect couplings 17.
C
018.196/09
x
5
7,8
936
AF
AF
H1
1
010.974/03
I
I
1413
15
12
3
3
2013
Maintenance of Water Separator 2-part Water Separator