English | 5 | Commissioning
26 | 89014478; 2020-06 | Operating instructions CTR Series
Connecting the warewasher to the waste water system
1
1
1
< 350 mm
< 350 mm
< 100 mm
Only
CTR MM / CTR ML
left-right
Ø Connect the waste water pipe (1) firmly to the warewasher.
Ø Guide and connect the waste water pipe with a slope (at least 3 °) to the on-site waste water connection.
Requirements for on-site installation
Connection Description
Location Left or right of the warewasher depending on the machine variant
Max. 100 mm above finished floor
Max. 350 mm above finished floor when the waste water pipe is led out of the side of
the warewasher. Retrofit kit 70014848 is required for this.
Construction Min. Ø70 mm with trap