EasyManua.ls Logo

Wolfgang Warmbier METRISO 3000 User Manual

Wolfgang Warmbier METRISO 3000
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Operating Instructions
METRISO3000
High Ohmic Resistance Tester for resistance point-to-point,
resistance to ground, surface and volume resistance measurements
3-349-644-03
2/2.13

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Wolfgang Warmbier METRISO 3000 and is the answer not in the manual?

Wolfgang Warmbier METRISO 3000 Specifications

General IconGeneral
BrandWolfgang Warmbier
ModelMETRISO 3000
CategoryTest Equipment
LanguageEnglish

Summary

METRISO 3000 Control Panel Overview

Fixed Function Keys Explained

Describes the function of keys like ESC, MEM, HELP, START, CONTIN.

Softkey Functions for Settings

Explains softkey functions like parameter selection, limit value specification, entry, and memory.

Instrument Power and Interfaces

Battery, Fuse, and Port Information

Details batteries, fuses, charger socket, RS 232, and USB ports.

Display Panel and Settings Overview

Display Panel Indicators

Explains battery level, measuring status, and memory occupancy displays.

Device Settings and Measuring Functions

Lists functions like RESD, R, U, Uesd, and tests like Battery test, SW-INFO.

METRISO 3000 Applications

Instrument Performance Features

Details measurements, display functions, and special features like data storage and USB interface.

Safety Features and Precautions

Initial Start-Up Procedures

Battery Installation and Charging

Explains battery replacement, type, and charging procedures using the Z502R charger.

Device Settings - SETUP Menu Navigation

LED and LCD Test Menu Operations

Details how to perform LED and LCD self-tests.

Adjusting Display Brightness and Contrast

Covers adjustments for display brightness and contrast.

Time, Language, and Default Settings

Explains setting time, language, auto-shutdown times, and restoring defaults.

General Operation and Instrument Setup

Connecting Instrument and Optical Indicators

Explains lead connection, optical indicators (LEDs) for limit values and interference voltage.

Power Management and Measurement Display

Details instrument power management, measurement value display, and memory.

Measuring Direct and Alternating Voltage

ESD Measurement Procedures

Discharging the Device Under Test (DUT)

Explains the procedure for safely discharging capacitive objects.

Setting ESD Measurement Parameters

Covers DUT parameter, measuring point, and limit value settings for documentation.

Resistance Measurements per IEC Standards

Measuring Resistance to Ground (IEC 61340-4-1)

Details how to measure resistance to ground (Rg) and groundable points (Rgp).

Measuring Person-to-Ground Resistance (IEC 61340-4-5)

Explains measuring person-to-ground resistance (Rg System/Rgp System).

Point-to-Point and Surface Resistance Measurements

Measuring Point-to-Point Resistance (Rp-p)

Explains measuring resistance between two points on a surface.

Measuring Surface Resistance (Rs)

Details measuring surface resistance of packaging materials using a ring probe.

Volume Resistance and Guard Terminal Measurements

Using the GUARD Terminal for High Resistance

Explains using the GUARD terminal to prevent surface current distortion in high resistance measurements.

High Resistance Tester Self-Test

Resistance Measurement - Ohm Function

Temperature and Humidity Measurement

METRISO 3000 Database Management

Creating ESD Control Element Structures

Explains creating structures for customer, building, and ESD control elements in the instrument.

Transferring Structures Between PC and Instrument

Details transferring structures between the PC and the test instrument via USB.

Creating Structures in the Test Instrument

Example: Creating Floor Covering Structure

Provides a step-by-step example for creating structural elements like floor covering.

Editing and Searching ESD Structures

Entering Designations for Structural Elements

Explains how to enter names for buildings and ESD control elements.

Searching for Structural Elements in Database

Details how to search for existing structural elements by ID or text.

Saving and Retrieving Measured Data

Saving Measurement Data with Comments

Explains the process of saving measurements to structural elements and adding comments.

Retrieving and Displaying Saved Measurements

Details how to display saved measurement data and their pass/fail status.

Data Evaluation, Reporting, and Barcodes

Using Barcode Scanners for Structure Management

Explains how to use scanners for searching and editing structural elements.

METRISO 3000 Characteristic Values

Measuring Ranges, Accuracy, and Specifications

Details RESD, R, and U measuring ranges, intrinsic error, and uncertainty.

Electrical Safety, EMC, and Fuses

Covers protection class, measuring category, EMC compliance, and fuse information.

Power Supply, Batteries, and Displays

Information on batteries, charger, and LED indicator functions.

Environmental Conditions and Mechanical Design

Measuring Uncertainty and IP Rating

Details display values for uncertainty and the meaning of IP protection codes.

Voltage vs. Resistance Characteristic Curves

Illustrates characteristic curves for voltage at device under test vs. resistance.

Instrument Maintenance Procedures

Battery Maintenance and Charging Procedures

Explains battery care, charging, and potential issues.

Fuse Replacement and Electronic Fuse Protection

Details checking and replacing the instrument's fuse and the electronic fuse protection.

Housing Care and Environmental Disposal

Proper Disposal of Instrument and Batteries

Information on proper disposal of the instrument and batteries according to regulations.

Appendix: Troubleshooting Error Messages

Interference Voltage, Fuse, and Offset Errors

Explains errors related to interference voltage, offset, and blown fuses.

Battery, Parameter, and Scanner Errors

Covers battery voltage errors, invalid parameter combinations, and scanner issues.

Troubleshooting and Optional Accessories

Database, Memory, and Deletion Errors

Explains errors related to saving data, full memory, and deletion prompts.

Optional Accessories for METRISO 3000

Lists optional items like the Master Battery Pack and Charger.