Safety Requirements and Regulations
Electric fences shall be installed and operated so that they cause no electrical hazard to
persons, animals or their surroundings.
Electric fence constructions, which are likely to lead to entanglement of animals or
persons, shall be avoided.
· An electric fence shall not be supplied from more than one energiser or from independent
fence circuits of the same energiser.
· The gap between two separate electric fences with different energisers shall be at least 2m.
· If this gap is to be closed, this should be affected by means of an electrically non conductive
material.
· Barbed or razor wire shall not be electrified by an energiser.
· Any part of an electric fence which is installed along a public path or highway shall be
identified by warning signs (p/no 33020) securely fastened to the fence posts or firmly
clamped to the fence wires at recommended intervals of approximately 10 metres to 50
metres, but not exceeding 90 metres. Warning signs should be at least 100mm x
200mm with a yellow background. The inscription shall be black and read: TAKE CARE -
ELECTRIC FENCE, it should be indelible and inscribed on both sides, lettering height of
at least 25mm.
· Except for low output battery operated energisers, the energiser earth electrode shall
penetrate the ground to a depth of at least 1m.
· Connecting leads that are run inside buildings shall be effectively insulated from the earth
structural parts of the building. This may be achieved by using double insulated high
voltage cable (p/no 31640). Connecting leads that are run underground shall be run in a
conduit of insulating material.
· Care shall be taken to avoid damage to the connecting leads due to the effects of animal
hooves or tractor wheels sinking into the ground.
· Connecting leads shall not be installed in the same conduit as the mains supply wiring,
communication cables or data cables.
· Connecting leads and electric fence wires shall not cross above overhead power or
communication lines.
· Crossings with overhead cables shall be avoided wherever possible. If such a crossing
cannot be avoided, it shall be made underneath the power line and as nearly as
possible at right angles to it.
· If connecting leads and electric fences are installed near an overhead power line the
clearances shall be:
1. Power Line Voltage: Under 1000 volts - Clearance: 3 Metres
2. Power Line Voltage: 1000 - 33,000 volts - Clearance: 4 Metres
3. Power Line Voltage: Over 33,000 volts - Clearance: 8 Metres
· If connecting leads and electric fence wires are installed near an overhead power line,
their height above ground shall not exceed 2m. This height applies either side of the
orthogonal projection of the outermost conductors of the power line on the ground
surface, for a distance of - 2m for power lines not exceeding 1000V - 15m for power
lines exceeding 1000V.
· A distance of 10m shall be maintained between the energiser and any other earth system
such as the household supply system protective earth or the telecom system earth.
· A warning sign as described earlier, shall be fitted to every point where persons may gain
ready access to the conductors.
· Where an electric animal fence crosses a public pathway, a non-electrified gate shall be
incorporated in the electric fence at that point or a crossing by means of stiles shall be
provided.
· At any such crossing, the adjacent electrified wires shall carry warning signs as described
earlier.
Please retain instructions for future reference.
SX300 Mk II Solar Powered
Energiser
Stockshop (L.E.) Ltd, Lodge Trading Estate, Broadclyst, Exeter, Devon, EX5 3BS
Tel: 01392 460077 Fax: 01392 460966 Email: sales@stockshop.co.uk
www.stockshop.co.uk
Question and Answer IconNeed help?

Do you have a question about the WOLSELEY SX300 Mk II and is the answer not in the manual?

WOLSELEY SX300 Mk II Specifications

General IconGeneral
Maximum Power (Pmax)300W
Open Circuit Voltage (Voc)40.5V
Short Circuit Current (Isc)9.4A
Module Efficiency18.3%
Temperature Coefficient of Isc0.05%/°C
Junction BoxIP67 Rated
Cable Length900mm
Maximum System Voltage1000V
FrameAnodized Aluminum Alloy
Connector TypeMC4

Summary

General Information

Safety and Handling Warnings

Crucial safety advice for operation, including electric shock risks and avoiding mains equipment.

Product Care and Suitability

Guidance on battery maintenance, solar panel cleaning, and animals/fencing types the energiser is suitable for.

Operating Instructions

Backup Battery Replacement

Procedure for changing the C cell backup batteries, including cover removal and polarity.

Earth Stake Installation

Instructions for installing the earth stake for optimal performance, including dampening soil.

Mounting and Connection

Steps for mounting the unit on the earth stake and connecting the earth and fence leads.

Indicator Light Interpretation

Explanation of the blue and yellow indicator lights indicating system status and solar activity.

Connecting an External Battery

External Battery Connection Procedure

How to connect the energiser to external 6v, 9v, or 12v batteries using the supplied lead kit.

Safety Requirements and Regulations

General Electric Fence Safety

Rules for safe installation and operation, avoiding entanglement and ensuring proper gaps.

Warning Signage Requirements

Specifications for warning signs needed along public paths and near conductors.

Lead and Wire Clearances

Regulations for clearances from overhead power lines and other earth systems.