Accuset 2 Troubleshooting
Diagnostic Screen
Accuset 2 Troubleshooting ASdoc100119 3-5
3
3.3 Diagnostic Screen
The diagnostic screen can be used to help diagnose battery, up/down and power feed
motors and power feed potentiometer problems should they occur.
See Figure 3-5. To display the Diagnostic Screen, push the Up button while in Manual
Mode to display Configuration Menu 1. Select Other to display Configuration Menu 2.
Push the Diagnostic button to display the Diagnostic Screen.
FIG. 3-5
CONFIGURATION MENU 2
Units
Language PID Values Diagnostic
6 - 3/4
Push Other button in Configuration
Menu 1 to enter Configuration Menu 2
Push UP button to enter
Configuration Menu 1
Push Diagnostic
button to enter
Diagnostic Screen
Auto-DownManual Auto-Up Pattern
CONFIGURATION MENU 1
Calib. HeadSave Set Kerf Other