EasyManua.ls Logo

Wood-mizer LT20 Series - Engine;Motor Specifications; Noise Level

Wood-mizer LT20 Series
137 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety & General Information
Engine/Motor Specifications
Safety & General Information 25doc052711 1-12
1
1.8 Engine/Motor Specifications
See Table 1-6. The power options available for the LT20 Series sawmill are listed below.
See Table 1-7. See the table below for power supply specifications for the LT20 sawmill.
DANGER! It is recommended that a 30mA Ground Fault Interrupter
(GFI) be used.
1.9 Noise Level
See Table 1-8. The average noise level is given in the table below
12
.
Engine/Motor Type Manufacturer Model No. Power Other Specifications
11HP Electric Tamel SA,
Poland
Sg 132S-2B HM 7.5 kW 14.5 A, 2925 r.p.m.
15HP Electric Tamel SA,
Poland
Sg 132S-2PC HM 11 kW 22.3 A 2920 r.p.m.
22HP Diesel Kubota D1005 22 HP 3600 r.p.m.
18HP Gasoline Kohler CH18 18HP 3750 r.p.m.
25HP Gasoline Kohler CH25 25HP 3600 r.p.m.,
725 cm
3
TABLE 1-6
3-Phase
Volts
Fused
Disconnect
Switch
Recommended
Wire Size
Non-Hydraulic 400 VAC 25 Amp
4 mm
2
up to 15 m of length
Hydraulic 400 VAC 35 Amp
6 mm
2
up to 15 m of length
TABLE 1-7
Sawmill Noise Level
LT20E15 L
EX8
= 79,6 dB (A)
LT20D22 L
EX8
= 85,6 dB (A)
LT20G25
L
EX8
= 88,1 dB (A)
1
1
The noise level measurement was taken in accordance with
PN-EN ISO 9612 Standard.
TABLE 1-8

Table of Contents