EasyManua.ls Logo

Wood-mizer LT40 B1 Series - Power Feed Problems

Wood-mizer LT40 B1 Series
157 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting Guide
Power Feed Problems
5
5-5 AHDSdoc092820 Troubleshooting Guide
5.3 Power Feed Problems
PROBLEM CAUSE SOLUTION
Power Feed Is Jerky At Low
Speeds Or Does Not Move
Until Speed Is Above Halfway
Mark.
Drum switch is dirty. Clean drum switch and lubricate
with contact grease supplied by
Wood-Mizer.
Drum switch contacts are bad Check that contacts are in good
condition and positively close cir-
cuit.
Speed switch is worn. Replace the speed switch.
Speed switch is blocked. Turn off the power for 20 sec-
onds and turn it back on.
Power Feed Is Jerky, But
Power Feed Motor Runs Prop-
erly At All Speeds.
Problem is mechanical. Refer to the Mechanical Test.
Power Feed Is Sluggish, Trips
Circuit Breaker Or Current
Limit.
Sawdust buildup in power
feed cover.
Remove power feed belt cover
and remove sawdust.