Maintenance
Safety Devices Inspection (CE Version Only)
Maintenance doc041620 3-7
3
2. Inspection of the control circuits after pressing the E-STOP button (A)
Start the main motor;
Press the E-STOP button located on the left side of the control box. The motor should stop.
With the E-STOP button pressed, try to move the saw head up and down (using the switch (B)
and Setworks button (C)) and forward/backward using the power feed switch (D). Both systems
should not start.
With the E-STOP button pressed, try to start the debarker blade motor (E) and move the
debarker arm (F). The debarker should remain turned off.
3. Inspection of the blade cover safety switches and their circuit
Turn on the main motor;
Open the blade housing cover;
The main motor should stop;
FIG. 3-3