MAINTENANCE
Electrical Up/Down System
MAINTENANCE 15doc042320 6-8
6
See Figure 6-4. Unbolt the up/down top guard. Loosen the motor mounting bolts. Use the
adjustment bolt shown below to adjust the belt tension. Tighten the motor mounting bolts. Replace
the top guard.
4. Every 200 hours of operation check and adjust the up/down motor brake air gap if necessary.
1
FIG. 6-5
FIG. 6-6
1. It does not concern the US version.
Motor Mounting
Bolts
Adjustment Bolt
Force=25
Deflection=
5mm
200