Ensure su󰈣cient clearance for access to the terminals (top and bottom) and
connectors located at the sides.
2. ▷
Mount the unit to the back panel and insert the screws.
3. ▷
Tighten the screws to a torque according to the quality class of the used screws.
Tighten the screws with a crosswise pattern to ensure even pressure
distribution.
If the thickness of the panel sheet exceeds 2.5 mm, be sure to use screws
with a length exceeding the panel sheet thickness by 4 mm.
3.2
Mount Unit (Plastic Housing)
Mount the unit either using the clamp fasteners (╚═▷ “3.2.1 Clamp Fastener Installation)
or the screw kit (╚═▷ “3.2.2 Screw Kit Installation).
Don't drill holes if you want to use the clamp fasteners. If the holes are drilled into
the panel, the clamp fasteners cannot be used anymore.
Some versions of the plastic housing are not equipped with nut inserts and may not
be fastened with the screw kit.
In order to enhance the protection to IP 66, fasten the unit with the screw kit instead
of the clamp fastener hardware.
33LS-5 v2 Series37650
3 Installation
3.2 Mount Unit (Plastic Housing)