21
RS-232
UI Element Description
RS-232 Parameter
Set the RS-232 parameters for the controlled display. For more information about the parameters, see the user guide of
your display device.
Default setting: 9600-8n1
Wakeup Command
Enter the RS-232 wakeup command of the controlled display device. For more information about the command, see the
user guide of your display device. If you want to disable this function, you can enter nothing here.
By default, it’s set as blank.
Standby Command
Enter the RS-232 standby command of a controlled display device. For more information about the command, see the user
guide of your display device. If you want to disable this function, you can enter nothing here.
By default, it’s set as blank.
RS-232 Hex String Enable
Enable: select to use the RS-232 standby and wakeup commands in hex string form to control your display devices. If
this item is enabled, make sure standby and wakeup commands are manually converted to their equivalent hex forms
rst and then input the RS-232 standby command and RS-232 wakeup command.
For example, RS-232 wake up command in hex form may be: 50 57 52 20 4F 4E 0D 0A.
Disable: Select to directly send the original standby or wakeup commands to control the attached display device.
Default setting: Disable
Apply Click to perform current settings.
Wakeup Click to send the Wakeup command dened in Wakeup Command eld to the connected display.
Standby Click to send the Standby command dened in Standby Command eld to the connected display.
Parameter Value Abbreviation
Baud rate
9600bps 9600
Data Bits 8bits 8
Parity None n
Stop Bits 1 1