975-0787-01-01 5
Features
GFCI Panel
3
4
1
2
Feature Description
1 GFCI cover is rem
oved when installing a GFCI
outlet. Location of GFCI receptacles.
2 20 A supplementary protector
with reset button
provides overload protection for the Freedom X GFCI
Device (PN: 808-9817). Press to recover from an
overload condition. In a hard wired installation, the
supplementary protector does not protect output
wiring.
3 Ventilation grille (o
penings) must not be obstructed
for the proper operation of the cooling fan and
inverter. When the inverter is mounted, the ventilation
grille must not point up or down.
Cooling fans turn on when
the internal temperature
reaches a set point temperature.
4 Grounding lug prov
ides a ground path for the
Freedom X chassis to the DC system ground.
Freedom X Series INV Owners Guide.book Page 5 Tuesday, June 27, 2017 4:10 PM