Adjusting Feature Settings in Configuration Mode
Inverter Output Power
Limit (Freedom X 1000)
 .  to .
The wattage setting value can be adjusted by 100-watt increments. Use
with Inverter Output Power Limit Timer especially when pairing with a
lithium ion battery.
Inverter Output Power
Limit (Freedom X 2000)
 .  to .
Inverter Output Power
Limit Timer
  to , 
When the range is from 1 to 20, the timer setting value can be adjusted by
1-second increments. When the range is from 20 to 300, the timer setting
value can be adjusted by 10-second increments.
Use with Inverter Output Power especially when pairing with a lithium ion
battery. The timer is automatically disabled if the maximum Inverter
Output Power limit is selected.
Transfer Mode
   (
appliance
),
 (UPS)
Selecting  - appliance sets the transfer time from line to battery to
20
ms. Selecting  (uninterruptible power supply) sets the transfer time
from line to battery to 10 ms. NOTE: Do not connect motor loads when in
UPS transfer mode. See
“Inverter Applications” on page 64.
Utility AC Under Voltage
Level
   to 
Inverter Shutdown
Recovery
  
(
auto-restart
)
,

(
manual restart
)
The inverter shuts down when there is an over temperature, overload, and
short circuit condition. Selecting  (auto-restart) will allow the inverter
to recover automatically from a shutdown up to three times maximum.
Selecting
 (manual restart) allows the user to restart the inverter by
performing a manual reset, that is, by acknowledging the restart via the
display panel.