Xantrex AGS - DC CONNECTIONS; Controller Wiring Pinout and Function

Xantrex AGS
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
#18 AWG wire should be used. The in-line connector for the
Controller has the following DC connections.
NO. DESCRIPTION
1 START: Generator start signal contact.
2 STOP: Generator stop signal contact.
3 GENERATOR DC HOUR METER.
4 RESERVED (Future ignition lock-out).
5 POWER POSITIVE: Connect to house battery positive.
2-amp fuse required. See INSTALLATION NOTE page 10.
6 THERMOSTAT 1: Connected to positive signal from
thermostat/heating-cooling system, 12 VDC = ON.
7 THERMOSTAT 2: Connect to positive signal from thermo-
stat/heat-cooling system, 12 VDC = ON.
8 PREHEAT: Contact for generator preheat signal.
9 START COMMON: Generator Start signal contact. Typi-
cally connect to generator ground.
10 STOP COMMON: Generator Stop signal contact. Typically
connect to generator ground.
11 THERMOSTAT 3: Connected to positive signal from
thermostat/heating-cooling system, 12 VDC = ON. This is
only available on units over S/N 150.
12 BATT SENSE POSITIVE: Connect to house battery posi-
tive. 2-amp fuse required.
13 POWER/SENSE NEGATIVE: Connect directly to house
battery negative.
14 THERMOSTAT 1,3 COMMON: Contact for thermostat 1
and 3. Connected to ground.
15 THERMOSTAT 2 COMMON: Contact for thermostat 2.
Connected to ground.
16 PREHEAT COMMON: Contact for Preheat signal. Typically
connected to generator ground.