47
AC Output 2
AC Output 1
AC Input 2
AC Input 1
Ground Bus
Neutral 2 Bus
Inverter AC Sub Panel
L2 L1
12 VDC Battery Bank
Class T
Fuse
Freedom 458 Installation Option 4
Freedom 458 Model 20 D/D, 25 D/D, 30 D/D
Dual Input/ Dual Output
30 Amp Transfer of two Legs
of power (60 Amps total)
* Two Neutral buses are required
if Shore Power is supplied
from 2/ separate 30 A sources.
**Always consult Local and National
Electrical Codes for proper wire size
prior to installation.
Freedom 458
Inverter/Charger
10/3
AWG
Wire**
-
+
+
-
Neutral Bus
Ground Bus
30
From Shore or Generator
L2 Gnd
Main AC Panel
30
Neutral 1 Bus
AC Wire Colors
Hot = Black
Neutral = White
Ground = Green/bare
*
Neu
L1
Hot
Bus
Main Main