975-0753-01-01 25
Basic Installation Procedures
This guide for use by qualified personnel only.
5. Remove the DC wiring cover to expose the ignition control
terminals of the DC wiring compartment.
6. Move the jumper wire from the left-side position (factory
instal
led) to the right-side position on the Ignition
Controlposition terminal.
The jumper wire, depending on which position it is installed,
acts to
disable (factory left-side position), lock-out (middle
position), and switch to auto-on (right-side position) the
ignition control. See “Description of Ignition Control Methods”
on page 25 for more details.
NOTE: Do not
make any external connections to terminal A.
This can result in non-warranty damage to the unit.
7. Route the ignition control wire to the left side of the display
panel
.
8. Replace the DC wiring cover onto the
DC wiring compartment.
The ignition control wire should pass-through the hole on the
side
of the DC wiring cover.
Description of Ignition Control Methods
Off (Disabled) This is the default position. In this position,
there is no ignition control capability.
Ignition Lock-
out
In this position, when ignition voltage is
detected
at the ignition input terminal, inverter
mode remains on "standby" until the Power
button on the front panel is pressed to turn on
inverter power. When the ignition voltage stops,
inverter power stops.
Ignition Auto-
on
In this position, when ignition voltage is
detected
at the ignition input terminal, inverter
power is automatically turned on. When the
ignition voltage stops, inverter power stops.