Installation
2–16 975-0402-01-01
This guide for use by qualified installers only
6. Remove the AC (L, N, GND) wires from the AC wiring
compartment of the charger.
7. Feed the source AC wire through the included strain
relief. Position approximately 1" from end of jacketed
portion of the AC wiring.
8. Connect the AC wiring to the Truecharge™ 2 Battery
Charger pigtail wires, being sure to connect the line
conductor to the line, the neutral to the neutral, and the
ground to the ground. The pigtail wires are color coded
as follows:
Make the connections using crimp-on connectors or with
other approved connectors required by your code, and
suitable for your installation. For example, the ABYC
Standards and Recommended Practices for Small Craft
prohibit twist-on connectors for AC connections on a
boat. For other types of installation, refer to your
applicable code.
For marine installations, follow the connector
manufacturer’s procedure for installing butt splice
connectors.
Conductor Color code
Line Black or brown
Neutral White or blue
Ground Green with yellow stripe
TC2 Series BattChg Install Guide.book Page 16 Monday, June 30, 2008 3:18 PM