AC Input Specifications
975-0402-01-01 A–5
This guide for use by qualified installers only
AC Input Specifications
AC input voltage range Nominal: 120 Vac, 230 Vac, 240 Vac
Full Performance: 105 – 265 Vac ±4 Vac
Automatic derating to 80%: 90 – 104
±4 Vac
Maximum AC input current at 104 Vac at 208 Vac
TC1012: 2.5 A TC1012: 1.5 A
TC1512: 3.5 A TC1512: 2.0 A
TC2012: 4.5 A TC2012: 2.5 A
TC3012: 7.0 A TC3012: 3.5 A
TC4012: 9.0 A TC4012: 4.5 A
TC5012: 11.5 A TC5012: 5.5 A
TC6012: 13.5 A TC6012: 6.5 A
TC1524: 7.0 A TC1524: 3.5 A
TC2024: 9.0 A TC2024: 4.5 A
TC3024: 13.5 A TC3024: 7.0 A
TC5024: 22.5 A TC5024: 11.5 A
Power factor at rated load 0.95
Frequency 47 – 63 Hz
Efficiency – peak 12 V units: 77% @ 120 Vac, 80% @
230 Vac
24 V units: 85% @ 120 Vac, 87% @
230 Vac
Surge protection Line-to-neutral surge protector rated at 275
Vac
TC2 Series BattChg Install Guide.book Page 5 Monday, June 30, 2008 3:18 PM