EasyManua.ls Logo

Xantrex XDC - SCPI Commands for Digital Interfaces (Continued); Auto Sequence Operation Control via SCPI

Xantrex XDC
254 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Operation
SCPI Commands for Digital Interfaces
140 Operating Manual for XDC Series Power Supply
Auto
Sequence
Operation
Select Sequence to Run
PROGram:NAME <sequence_number>
where <sequence_number> can range from 1 to 10.
Operation
Running
PROGram :STATe [RUN|PAUSe|STOP]
Once the programmed sequence has been selected, you can start it by setting the
state to RUN, by sending the command PROG:STAT RUN.
At any time you can pause the sequence by sending PROG:STAT PAUS.
A paused sequence will cause the supply to hold the output levels at the setpoints
programmed by the current step. To resume, set the state to RUN again.
To end the sequence operation, send the command PROG:STAT STOP.
Sending RUN will restart the auto sequence program from the first step.
You can query the state of the selected auto sequence program with
PROG:STAT?
Trigger
If the auto sequence was programmed to wait for a trigger, the power supply holds
the output levels at the programmed setpoints until a trigger is received. It then
advances to the next step. A trigger must come from the selected trigger source.
Skipping a Step
PROGram:STEP:NEXT
Querying Operation
PROGram:STEP:EXEC?
You can query the step number that is currently operating.

Table of Contents