EasyManua.ls Logo

Xantrex XHR 100-10 - SW1 Programming Switch Functions

Xantrex XHR 100-10
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Features and Specifications
Rear Panel Connectors and Switch
Revision A 19
Figure 1.3 Rear Panel with High Voltage Output Connector
(For 60 V to 600 V models.)
SW1
Programming
Switch
The SW1 Programming, Monitoring, and Shutdown Select switch is an 8-position
piano DIP switch located on the power supplys rear panel. The SW1 switch enables
you to choose:
Output voltage and current limit programming scales
Output voltage and current monitor scales
Remote shutdown circuit logic
Resistive programming of output voltage or current limit
Over temperature shutdown mode
The power supply is shipped with the SW1 switch set in the default operating
configuration, as illustrated in Figure 1.4.
Figure 1.4 SW1 Programming Switch
(Shown in its default configuration.)
100/120/200/240V
50/60 HZ
1300VA
100/120/200/240V
50/60 HZ
1300VA
Local Sense Wires
(See page 48.)
DC Output and Local Sense Connector
(See page 39 for more information.)
TM-XROP-01XN.book Page 19 Monday, March 22, 2004 4:10 PM