Installation
Load Connection
Revision A 43
Figure 2.4 Typical Load Connection Hardware
(For 7.5 V to 40 V models.)
To make load connections to a 7.5 V, 130 A power supply:
1. Install a connecting wire terminal lug to load wiring. See Figure 2.4.
2. Fasten wire terminal lugs to bus bars with 1/4in. x 1/2in. (M6 x 12 mm) screws,
1/4in. (M6) internal tooth lock washers, and hex nuts as shown.
Note:Bus bar hole sizes are: 2 of 0.257in. (6.50 mm) diameter (D); 1 of 0.191in.
(4.83 mm) D; and 2 of 0.156in. (3.95 mm) D.
Wire Terminal
Lug (2 places)
Screw (2 places)
Hex Nut
(2 places)
Lock Washer
(2 places)
TM-XROP-01XN.book Page 43 Monday, March 22, 2004 4:10 PM