Network Installation
975-0298-01-01 2–3
Network Installation
This section describes requirements for installing the System Control
Panel as part of a Xanbus network-managed power system. For the
system to function properly, requirements for network layout and
termination must be followed.
Network Components
A Xanbus network consists of the following components:
• Xanbus-enabled devices—these include the System Control Panel,
the XW Series Inverter/Charger, XW-Automatic Generator Start
(AGS), and XW Charge Controller. The network can consist of up to
eight Xanbus-enabled devices. A typical XW Power System can
include three inverter/chargers, two charge controllers, one AGS and
one System Control Panel. Only one System Control Panel can be
installed on the Xanbus network.
• Xanbus power supply—the network requires a power supply capable
of providing 15 Vdc/200 mA to each device. The XW Series Inverter/
Charger provides network power, but if no inverter/charger is
installed, an external power supply is required. Contact Xantrex for
more information.
• Xanbus cables—each Xanbus-enabled device is connected by a
Category 5 (CAT 5 or CAT 5e) cable. The cable consists of eight
conductors in four twisted pairs with an RJ-45 modular connector
wired to the T568A standard. See Figure 2-2 on page 2–4. A 7 foot
(2.1 meter) network cable is included with the System Control Panel.
If more cables or a different length are required, these standard cables
can be purchased from Xantrex or any computer supply store.
WARNING: Explosion hazard
The System Control Panel is not Ignition Protected. Do not install in areas
requiring Ignition-Protected equipment, such as areas containing gasoline
engines, tanks, or fuel-line fittings.
CAUTION: Equipment damage
Do not use crossover cable.