Network Installation
975-0298-01-01 2–5
Network connectors (optional, depending on network layout)—the
three-way connector houses three RJ-45 inputs that provide a device
connection point on a multi-drop backbone layout (see “Multi-Drop
Backbone Layout” on page 2–6). All three inputs are wired
identically and can accept either Xanbus cables or terminators. One
input is available for connecting to a Xanbus-enabled device. The
remaining inputs are reserved for connection to other network
connectors, a Xanbus cable terminated with a female terminator, or a
male terminator.
The network connector is mounted to a bulkhead or a wall, as shown
in Figure 2-4.
Figure 2-3
Network Terminators
Male network terminator Female network terminator
Figure 2-4
Three-Way Network Connector
To network connector
To network connector
or terminator
To device