Mounting the System Control Panel
975-0298-01-01 2–11
Mounting the System Control Panel
The System Control Panel can be mounted three ways:
• Flush mounted through an opening in a wall using the mounting plate
• Surface mounted using the mounting bracket
• Flush mounted through an opening in a wall and secured with four #6
screws.
To flush mount the System Control Panel with mounting plate:
1. Using a jigsaw and the supplied template sticker as a guide, cut out
the hole for the mounting plate. The mounting plate fastens to walls
up to ¾ inch (19 mm) thick.
2. Route the Xanbus cable(s) inside the wall and through the opening.
3. Insert the mounting plate with the two tabs in a vertical position into
the hole (see Figure 2-7).
4. Secure the mounting plate by tightening the two screws to rotate the
tabs to the horizontal position (see Figure 2-8) and pull the tabs tight
against the inner surface of the wall. Be careful not to overtighten the
screws and damage the wall.
WARNING: Shock hazard
Before making an opening in a wall or panel, ensure there is no wiring or other
obstruction within the wall.
Figure 2-7
Inserting the Mounting Plate
Tabs in vertical position