June 2014
6-22
Xerox® WorkCentre® 3025 Multifunction Printer Service Manual
Entering Diagnostic Mode
General Procedures and Information
NOTE:
* Indicates features included in the 3025NI model only.
NOTE:
** Indicates that there is a function in Diagnostics that allows for entry of the serial number
using the keypad (3025NI). From Diagnostic Mode, (Ref. GP 1) select: [Data Set Up>Set
Serial Number] then, using the keypad, enter the serial number. Press the <OK> button to
confirm selections. This function allows numeric entries only. For serial numbers containing
alpha characters (letters) use the serial number writing tool; USB_Serial.V1.02.exe.
Table 1 Diagnostic Mode Menu - Data Setup
Level 1 Level 2 Level 3 Level 4
Data Setup *Send Level 9-15 12
*DTMF Level (High) 0-15 (Low) 0-15
*Pause Time 1-9
*Dial Mode Tone/Pulse
*Modem Speed 33.6
28.8
14.4
12.0
9.6
4.8
*Error Rate 10%
5%
Clear All Memory Set options Clearing Memory
Toner Low Level 1-30%
Clear Counts Enter <1934>ADF Scan
Platen Scan
Fuser
Transfer Roller
Pickup Roller
ADF Roller
ADF Rubber Pad
Engine Footer Off/On
*Dial Tone Off/On
*Caller ID Off/On
*Busy Tone Off/On
Wrap Jam Clear No/Yes
F/W Upgrade Off/On
**Set Serial No. Enter machine serial
number (Numeric
characters only)