03/02 How to use the Diagnostic C/E Mode
WorkCentre Pro 423/428 2-205 CHAPTER 2 TROUBLESHOOTING
Chain Function Item Description Default Description Access by
58 582 Time allocation for the Transmission
charge (0 to 3)
00:Daytime 01:Night 10:Late night
11:Not used
0:00:XXXX XXbb 1:00:XXXX
bbXX 2:00:XXbb XXXX
3:00:bbXX XXXX
170(AA) With the optional Operator card Management kit installed communication
made between midnight and 3:59 will be calculated and charged as
specified.
CE
58 583 Time allocation for the Transmission
charge (4 to 7)
00:Daytime 01:Night 10:Late night
11:Not used
4:00:XXXX XXbb 5:00:XXXX bbXX
6:00:XXbb XXXX 7:00:bbXX XXXX
170(AA) With the optional Operator card Management kit installed communication
made between midnight and 7:59 will be calculated and charged as
specified.
CE
58 584 Time allocation for the Transmission
charge (8 to 11)
00:Daytime 01:Night 10:Late night
11:Not used
8:00:XXXX XXbb 9:00:XXXX bbXX
10:00:XXbb XXXX 11:00:bbXX
XXXX
00 With the optional Operator card Management kit installed communication
made between midnight and 11:59 will be calculated and charged as
specified.
CE
58 585 Time allocation for the Transmission
charge (12 to 15)
000:Daytime 01:Night 10:Late
night 11:Not used
12:00:XXXX XXbb 13:00:XXXX
bbXX 14:00:XXbb XXXX
15:00:bbXX XXXX
00 With the optional Operator card Management kit installed communication
made between midnight and 15:59 will be calculated and charged as
specified.
CE
58 586 Time allocation for the Transmission
charge (16 to 19)
00:Daytime 01:Night 10:Late night
11:Not used
16:00:XXXX XXbb 17:00:XXXX
bbXX 18:00:XXbb XXXX
19:00:bbXX XXXX
64(40) With the optional Operator card Management kit installed communication
made between midnight and 19:59 will be calculated and charged as
specified.
CE
58 587 Time allocation for the Transmission
charge (20 to 23)
00:Daytime 01:Night 10:Late night
11:Not used
20:00:XXXX XXbb 21:00:XXXX
bbXX 22:00:XXbb XXXX
23:00:bbXX XXXX
149(95) With the optional Operator card Management kit installed communication
made between midnight and 23:59 will be calculated and charged as
specified.
CE
58 590 Forced polling at Printer failure 0:Disable 1:Enable forced poll 00 When the maintenance service is conducted for the problem caused by
the IOT failure, there may be cases that the data received must be
deleted or retrieved urgently as required by the customer. In such
cases, change the data to “Enable forced poll” and the data stored in the
memory can be retrieved by polling from the remote terminal. However,
as you may have to handle the customer information directly, you need
to get prior approval by the customer and let the customer know that all
information cannot always be retrieved.
CE
58 591 Permitting the existence of multiple time-
specified polling
0:Permit 1:Do not permit 01
58 592 Restricting Forced 4800 bps setting menu
to support PTT
0: Do not restrict 1: Restrict 00