Loading...
03/02 2.3 Level 2 Troubleshooting
WorkCentre Pro 423/428 2-67 CHAPTER 2 TROUBLESHOOTING
2.3.1.14 Internal Codes List
Internal
Code
Error Description Corrective Action
0273 Character print data (Character info.)
error. ERRHOSTJ_CHARA_TYPE
Replace OA I/F board.
0274
Character print data (Character length)
error. ERRHOSTJ_CHARA_LEN
Replace OA I/F board.
02A5
File error
Attempting to send empty page
Check/replace M/F MAIN PWB,
AM, and MMB.
035A No blank channel available for BP-F
device ( ERR_VCEM_NOCH )
System reset.
035B Attempting to connect or release port in
use by another job (
ERR_VSWSW_BUSY )
System reset.
05E0 JBIG/MMR decode error occurred with
G3 module transmission.
Check the transmitter parameters.
Check/replace M/F MAIN PWB.
Retry.
09E0 JBIG/MMR decode error occurred with
G4 module transmission.
Check the transmitter parameters.
Check/replace M/F MAIN PWB.
Retry.
8143 Line connection time out Replace NCU PWB.
Replace G4/ICM PWB/ROM.
Replace G3M PWB/ROM.
Replace G4M PWB/ROM.
8180 EM_PNLIF_ABNORMAL
PNL I/F DEVICE Handler received an
illegal command.
8181
EM_PNLIF_TxILLEGAL
Faulty send status at the occurrence of
PNL I/F send interrupt
8182 EM_PNLIF_RxILLEGAL
Faulty receive status at the occurrence
of PNL I/F receive interrupt
8183
EM_PNLIF_INTRILLEGAL
An illegal interrupt occurred with PNL I/F.
Check M/F MAIN PWB and
CONTROL PANEL for
connections. Replace M/F MAIN
PWB or CONTROL PANEL.
Internal
Code
Error Description Corrective Action
8184 EM_PNLIF_CHANNEL
PNL I/F logic channel failure: Selected
channel doesn’t exist, is already opened,
isn’t opened yet or is already closed.
8185
EM_PNLIF_FRAMELONG
Send/Receive Frame Length is over.
Check M/F MAIN PWB and
CONTROL PANEL for
connections. Replace M/F MAIN
PWB or CONTROL PANEL.
8186
EM_PNLIF_NOFRAME
Frame requested to read doesn’t exist.
8187
EM_PNLIF_RxFULL
Receive Buffer full
8188 User buffer full with received data.
(Serial data receive buffer to Panel
Monitor became full.)
8189 Abnormal serial receive data sequence
from PANEL
818A
Failed to notify completion of serial data
sending that is to panel.
818B
Failed to notify completion of serial data
receiving that is to panel.
81C0 An error was detected in the semaphore
controlling library.
Check/replace M/F MAIN PWB,
AM, and MMB.
81D0 DC I/F Monitor received an illegal event.
EM_DCIFM_ABNORMAL
81D1 EM_DCIFM_FRAMELONG
Receive frame length from DC SYS is
over.
Check M/F MAIN PWB and
MCU/SW PWB for connections.
Replace M/F MAIN PWB or
MCU/SW PWB.
81D2 A message was sent from DC to the
channel which is not open to MF.
(EM_DCIFM_CHAN_CLOSE)
81D3
A message with an unknown address
was sent from DC.
(EM_DCIFM_INVAILD_ADDR)